Hall-Effect Current Sensor

HS-PKF  Small current range / PCB-mounting type RoHS compliant

HS-PKF

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 50A–100A
  • Realized high precision and compact size
  • Superior in response, linearity and temperature characteristics

Applications

Inverters, Servo drivers, Power supply equipment, NC machine tools

Detailed data

Electrical characteristics Ta=25℃

Output type Current output type
Type HS-PKF050A0025B15 HS-PKF100A005B15
Rated current [If] ±50A ±100A
Continuously flowing DC current ±50A ±71A
Saturation current [Is] ±100A ±160A
Linearity limits 0~±100A (RL=45Ω) 0~±160A (RL=45Ω)
Rated output [Ih] +If I0+25mA±0.5% I0+50mA±0.5%
Rated output [Ih] -If I0-25mA±0.5% I0-50mA±0.5%
Residual output [I0] Within ±0.2mA
Output linearity Within ±0.15% at If
Second coil resistance Approx. 82Ω
Response time Within 0.5μs (at di/dt=If/μs)
Response performance Within 10% (at di/dt=If/μs)
Hysteresis voltage range Within 0.15mA
Output Temp. Coef. Within ±0.01%/℃
Residual output Temp. Coef. Within ±0.005mA/℃
Control power supply ±15V±5%
Consumption current 20mA+(Input current/2000)
Operating Temp. -25℃~+85℃
Storage Temp. -40℃~+90℃
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated residual voltage is the one after the core hysteresis is removed.
Note2)
Energization time of saturation current shall be within 1 second.
Note3)
Energization time of continuous live DC current x150% shall be within 1 minute.