Hall-Effect Current Sensor

HS-PKD  Small current range / PCB-mounting type RoHS compliant

HS-PKD

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 50A–100A
  • Realized high precision and compact size
  • Superior in response, linearity and temperature characteristics
  • Both the voltage output and the current output were prepared

Applications

Inverters, Servo drivers, Power supply equipment, NC machine tools

Detailed data

Electrical characteristics Ta=25℃

Output type Voltage output type Current output type
Type HS-PKD
050V4B15
HS-PKD
100V4B15S
HS-PKD
150V4B15S
HS-PKD
050A0025B15
HS-PKD
100A005B15
Rated current [If] ±50A ±100A ±150A ±50A ±100A
Continuously flowing DC current ±50A ±72A ±108A ±50A ±72A
Saturation current [Is] ±125A ±250A ±375A ±100A ±150A
Linearity limits 0~±100A 0~±200A 0~±300A 0~±100A (RL=100~180Ω) 0~±150A (RL=120Ω)
Rated output [Vh,Ih] +If V0+4V±1% (RL=10kΩ) I0+25mA±1% I0+50mA±1%
Rated output [Vh,Ih] -If V0-4V±1% (RL=10kΩ) I0-25mA±1% I0-50mA±1%
Residual output [V0,I0] Within ±20mV Within ±0.2mA
Output linearity Within ±0.5%
Second coil resistance Approx. 47Ω Approx. 63Ω Approx. 38Ω
Response time Within 1μs (The smaller one on either at di/dt = 100A/μs or If/μs.)
Response performance Within 10%
Hysteresis voltage range Within 20mV Within 0.2mA
Output Temp. Coef. Within ±0.01%/℃
Residual output Temp. Coef. Within ±0.8mV/℃ Within ±0.01mA/℃
Control power supply ±15V±5%
Consumption current 20mA+(Input current/2500) 20mA+(Input current/3200) 20mA+(Input current/2000)
Operating Temp. -10℃~+80℃
Storage Temp. -15℃~+85℃
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated residual voltage is the one after the core hysteresis is removed.
Note2)
Energization time of saturation current shall be within 1 second.
Note3)
Energization time of continuous live DC current x150% shall be within 1 minute.

Consultations and Inquiries about Our Products

Current sensor user's guide

When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.

Click here for FAQs about current sensors

Contact us by e-mail or phone

+81-865-66-4877

PageTop