Hall-Effect Current Sensor

HS-PHA  Small current range / PCB-mounting type RoHS compliant

HS-PHA

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 5A–30A
  • Realized high precision and compact size
  • Superior in response, linearity and temperature characteristics

Applications

Inverters, Servo drivers, Power supply equipment, NC machine tools

Detailed data

Electrical characteristics Ta=25℃

Output type Voltage output type
Type HS-PHA05V4B15 HS-PHA10V4B15 HS-PHA20V4B15 HS-PHA30V4B15
Rated current [If] ±5A ±10A ±20A ±30A
Continuously flowing DC current ±3.6A ±7.2A ±14.4A ±21.6A
Saturation current [Is] ±12.5A ±25A ±50A ±75A
Linearity limits 0~±10A 0~±20A 0~±40A 0~±60A
Size of primary winding Φ0.8 Φ1.0 Φ1.3 Φ1.3
Turns 6 3 1 1
Rated output [Vh] ±4V±1.5% (RL=10kΩ)
Residual output [V0] Within ±30mV
Output linearity Within ±0.5%
Response time Within 3μs (at di/dt=If/μs)
Response performance Within 20%
Hysteresis voltage range Within 50mV
Output Temp. Coef. Within ±0.04%/℃
Residual output Temp. Coef. Within ±1mV/℃
Control power supply ±15V±5%
Consumption current 20mA+(Input current x N)/1270
Operating Temp. -10℃~+80℃
Storage Temp. -15℃~+85℃
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated residual voltage is the one after the core hysteresis is removed.
Note2)
Energization time of saturation current shall be within 1 second.
Note3)
Energization time of continuous live DC current x150% shall be within 1 minute.

Consultations and Inquiries about Our Products

Current sensor user's guide

When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.

Click here for FAQs about current sensors

Contact us by e-mail or phone

+81-865-66-4877

PageTop