Hall-Effect Current Sensor

HS-K  Medium current range / Bolt on type RoHS compliant

HS-K

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 300A–500A
  • Superior in response, linearity and temperature characteristics
  • Both the voltage output and the current output were prepared

Applications

Inverters, Power supply equipment

Detailed data

Electrical characteristics Ta=25℃

Output type Voltage output type Current output type
Type HS-K300V4B15 HS-K400V4B15 HS-K500V4B15 HS-K300A0075B15 HS-K400A010B15 HS-K500A010B15
Rated current [If] ±300A ±400A ±500A ±300A ±400A ±500A
Continuously flowing DC current ±600A ±800A ±1000A ±600A ±800A ±1000A
Saturation current [Is] ±600A ±800A ±1000A ±600A ±800A ±1000A
Linearity limits 0~±600A 0~±800A 0~±1000A 0~±600A (RL=30Ω) 0~±800A (RL=10Ω) 0~±1000A (RL=1Ω)
Rated output [Vh,Ih] ±4V±1% (RL=10kΩ) ±75mA±1% ±100mA±1%
Residual output [V0,I0] Within ±20mV Within ±0.2mA
Output linearity Within ±0.5%
Second coil resistance Approx. 31Ω Approx. 42Ω Approx. 31Ω Approx. 42Ω
Response time Within 1μs (at di/dt=100A/μs)
Response performance Within 20%
Hysteresis voltage range Within 20mV Within 0.2mA
Output Temp. Coef. Within ±0.02%/℃
Residual output Temp. Coef. Within ±1mV/℃ Within ±0.01mA/℃
Control power supply ±15V±5%
Consumption current 20mA+(Input
current/4000)
20mA+(Input
current/5000)
20mA+(Input
current/4000)
20mA+(Input
current/5000)
Operating Temp. -10℃~+80℃
Storage Temp. -15℃~+85℃
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated residual output is the one after the core hysteresis is removed.