Hall-Effect Current Sensor

HP-AR  Medium current range / Bolt on type CERoHS compliant

HP-AR

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 200A–1150A
  • Tri-phase current sensor in the same housing (Good fit 47mm/48mm pitch IGBT Modules)
  • Operating temperature range: -40℃ to +125℃
  • Use high performance programmable Hall IC
  • 5V single power supply, ratiometric output (sensitivity and offset)

Applications

xEV inverters (HEV, EV, PHEV, etc)

Detailed data

Electrical characteristics Ta=25℃

Type HP-AR200V2PP5 HP-AR400V2PP5 HP-AR600V2PP5 HP-AR800V2PP5 HP-ARE115V2PP5
Rated current [If] ±200A ±400A ±600A ±800A ±1150A
Output voltage [Vout] Vout=(Vcc/5)・(V0+G・Ip) (Note3)
Sensitivity [G] (Note4) 10mV/A 5mV/A 3.33mV/A 2.5mV/A 1.74mV/A
Load resistance [RL] ≧2.5kΩ
Sensitivity error I=±If ±1% ±1.5%
Offset voltage [V0] I=0 Vref ±18mV (Vref=Vcc/2)
Output linearity Within ±1%
Response time Within 5μs (at di/dt=100A/μs) @LPF(fc=133kHz) connected
Response performance Within 10% (at di/dt=100A/μs) @LPF(fc=133kHz) connected Within 15% (at di/dt=100A/μs) @LPF(fc=133kHz) connected
Hysteresis voltage range ±22mV ±15mV ±12mV ±10mV ±9mV
Sensitivity Temp. Coef. ±3%
Offset voltage Temp. Coef. ±30mV
Control power supply [Vcc] +5V±5%
Ratiometricity error
[+5V±5%]
Sensitivity
±0.5%
Ratiometricity error
[+5V±5%]
Offset voltage
±0.4%
Consumption current Within 40mA
Operating Temp. -40℃~+125℃
Storage Temp. -40℃~+125℃
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated offset voltage is the one after the core hysteresis is removed.
Note2)
Output specifications: maximum output current ≦2mA, Load capacitance ≦100pF
Note3)
Vcc: Control power supply, V0: Offset voltage, G: Sensitivity, Ip: Primary current
Note4)
Sensitivity: G=2000mV/If

Consultations and Inquiries about Our Products

Current sensor user's guide

When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.

Click here for FAQs about current sensors

Contact us by e-mail or phone

+81-865-66-4877

PageTop