HC-WT Medium current range /
Features
- Rated current: 50A–300A
- Two circuits can be measured at the same time
- Single-power supplies also available
Applications
Inverters, Power supply equipment, NC machine tools
Electrical characteristics Ta=25℃
Type | HC-WT050V4B15 | HC-WT100V4B15 | HC-WT300V4B15 |
---|---|---|---|
Rated current [If] | ±50A | ±100A | ±300A |
Saturation current [Is] | ±150A | ±300A | ±700A |
Linearity limits | 0~±150A | 0~±300A | 0~±600A |
Rated output [Vh] | ±4V±1.5% | ±4V±1% | |
Residual output [V0] | Within ±50mV | Within ±30mV | |
Output linearity | Within ±1% | ||
Response time | Within 10μs (The smaller one on either at di/dt = 100A/μs or If/μs.) | ||
Response performance | Within 10% | ||
Hysteresis voltage range | Within 30mV | ||
Output Temp. Coef. | Within ±0.08%/℃ | ||
Residual output Temp. Coef. | Within ±2.5mV/℃ | Within ±1.5mV/℃ | |
Control power supply | ±15V±5% | ||
Consumption current | Within 60mA | ||
Operating Temp. | -10℃~+80℃ | ||
Storage Temp. | -15℃~+85℃ | ||
Dielectric withstand voltage | 2500V AC 50/60Hz 1minute | ||
Insulation resistance | Not less than 500MΩ 500V DC |
- Note1)
- The indicated rated output is the one when no load is applied.
- Note2)
- The indicated residual voltage is the one after the core hysteresis is removed.