Hall-Effect Current Sensor

HC-TNG  Medium current range / Bolt on type CERoHS compliant

HC-TNG

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 50A–800A
  • Superior noise-resistance
  • Low-profile realized to our conventional products (HC-TN)
  • Well isolated for European Standards
  • Bus bar mounting type

Applications

Inverters, Servo drivers, Power supply equipment, Uninterruptible power supply (UPS), NC machine tools, Welders

Detailed data

Electrical characteristics Ta=25℃

Type HC-TNG050V4B15 HC-TNG100V4B15 HC-TNG300V4B15 HC-TNG600V4B15 HC-TNG800V4B15
Rated current [If] ±50A ±100A ±300A ±600A ±800A
Saturation current [Is] ±150A ±300A ±900A ±1000A
Linearity limits 0~±150A 0~±300A 0~±700A 0~±900A
Rated output [Vh] RL=10kΩ V0±4V±1%
Residual output [V0] Within ±50mV Within ±30mV
Output linearity Within ±1%
Response time Within 5μs (The smaller one on either at di/dt = 100A/μs or If/μs.)
Response performance Within 10%
Hysteresis voltage range Within 30mV
Output Temp. Coef. Within ±0.1%/℃
Residual output Temp. Coef. Within ±3mV/℃ Within ±1.5mV/℃ Within ±1mV/℃
Control power supply ±15V±5%
Consumption current Within 20mA
Operating Temp. -25℃~+85℃
Storage Temp. -25℃~+85℃
Dielectric withstand voltage 4000V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated residual voltage is the one after the core hysteresis is removed.

Consultations and Inquiries about Our Products

Current sensor user's guide

When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.

Click here for FAQs about current sensors

Contact us by e-mail or phone

+81-865-66-4877

PageTop