Hall-Effect Current Sensor

HC-PT  Medium current range / PCB-mounting type RoHS compliant

HC-PT

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 50A–300A
  • Three circuits can be measured at the same time
  • Ferrite core specification also available
    (Rated current 50A ~ 100A)
  • Single-power supplies also available

Applications

Inverters, Power supply equipment, NC machine tools

Detailed data

Electrical characteristics Ta=25℃

Type HC-PT050V4B15 HC-PT100V4B15 HC-PT150V4B15 HC-PT200V4B15 HC-PT300V4B15
Rated current [If] ±50A ±100A ±150A ±200A ±300A
Saturation current [Is] ±150A ±300A ±450A ±600A ±600A
Linearity limits 0~±150A 0~±300A 0~±400A 0~±400A 0~±400A
Rated output [Vh] ±4V±1%
Residual output [V0] Within ±50mV
Output linearity Within ±1%
Response time Within 10μs (The smaller one on either at di/dt = 100A/μs or If/μs.)
Response performance Within 10%
Hysteresis voltage range Within 200mV
Output Temp. Coef. Within ±0.1%/℃
Residual output Temp. Coef. Within ±4mV/℃ Within ±3mV/℃ Within ±2mV/℃
Control power supply ±15V±5%
Consumption current Within 60mA
Operating Temp. -10℃~+80℃
Storage Temp. -15℃~+85℃
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated rated output is the one when no load is applied.
Note2)
The indicated residual voltage is the one after the core hysteresis is removed.

Consultations and Inquiries about Our Products

Current sensor user's guide

When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.

Click here for FAQs about current sensors

Contact us by e-mail or phone

+81-865-66-4877

PageTop