Hall-Effect Current Sensor

HC-PRD  Small current range / PCB-mounting type RoHS compliant

HC-PRD

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 25A–50A
  • Well isolated for European Standards
  • Compact design: height has been kept down to 12.0 mm
  • Single-power supplies also available
  • Two circuits can be measured at the same time

Applications

Inverters, Servo drivers, NC machine tools

Detailed data

Electrical characteristics Ta=25℃

Type HC-PRD25V4B15 HC-PRD30V4B15 HC-PRD40V4B15 HC-PRD50V4B15
Rated current [If] ±25A ±30A ±40A ±50A
Continuously flowing DC current ±35A ±35A ±35A ±35A
Saturation current [Is] ±75A ±90A ±90A ±90A
Linearity limits 0~±75A 0~±75A 0~±75A 0~±75A
Size of primary busbar □1x2 □1x2 □1x2 □1x2
Turns 1 1 1 1
Rated output [Vh] +If V0+4V±1.5% (RL=10kΩ)
Rated output [Vh] -If V0-4V±1.5% (RL=10kΩ)
Residual output [V0] Within ±100mV
Output linearity Within ±1%
Response time Within 10μs (at di/dt=If/μs)
Response performance Within 10%
Hysteresis voltage range Within 120mV
Output Temp. Coef. Within ±0.1%/℃
Residual output Temp. Coef. Within ±3mV/℃
Control power supply ±15V±5%
Consumption current Within 40mA
Operating Temp. -10℃~+80℃
Storage Temp. -15℃~+85℃
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated residual voltage is the one after the core hysteresis is removed.

Consultations and Inquiries about Our Products