Hall-Effect Current Sensor

HC-PRC  Small current range / PCB-mounting type RoHS compliant

HC-PRC

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 3A–20A
  • Well isolated for European Standards
  • Compact design: height has been kept down to 12.0 mm
  • Single-power supplies also available
  • Two circuits can be measured at the same time

Applications

Inverters, Servo drivers, NC machine tools

Detailed data

Electrical characteristics Ta=25℃

Type HC-PRC03V4B15 HC-PRC05V4B15 HC-PRC10V4B15 HC-PRC20V4B15
Rated current [If] ±3A ±5A ±10A ±20A
Continuously flowing DC current ±3.5A ±3.5A ±8.8A ±8.8A
Saturation current [Is] ±9A ±15A ±30A ±45A
Linearity limits 0~±7.5A 0~±12.5A 0~±25A 0~±37.5A
Size of primary winding Φ0.45 Φ0.45 Φ0.9 Φ0.9
Turns 10 6 3 2
Rated output [Vh] +If V0+4V±1.5% (RL=10kΩ)
Rated output [Vh] -If V0-4V±1.5% (RL=10kΩ)
Residual output [V0] Within ±100mV
Output linearity Within ±1%
Response time Within 10μs (at di/dt=If/μs)
Response performance Within 10%
Hysteresis voltage range Within 120mV
Output Temp. Coef. Within ±0.1%/℃
Residual output Temp. Coef. Within ±3mV/℃
Control power supply ±15V±5%
Consumption current Within 40mA
Operating Temp. -10℃~+80℃
Storage Temp. -15℃~+85℃
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated residual voltage is the one after the core hysteresis is removed.

Consultations and Inquiries about Our Products

Current sensor user's guide

When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.

Click here for FAQs about current sensors

Contact us by e-mail or phone

+81-865-66-4877

PageTop