Hall-Effect Current Sensor

HC-PDG  Small current range / PCB-mounting type RoHS compliant

HC-PDG

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 5A–50A
  • Superior noise-resistance
  • Superior saturation characteristics
  • Reduced height compact design
  • Single-power supplies also available

Applications

Inverters, Servo drivers, Power supply equipment, Uninterruptible power supply (UPS), NC machine tools, Welders

Detailed data

Electrical characteristics Ta=25℃

Type HC-PDG05V4B15 HC-PDG10V4B15 HC-PDG20V4B15 HC-PDG30V4B15 HC-PDG50V4B15
Rated current [If] ±5A ±10A ±20A ±30A ±50A
Continuously flowing DC current ±8.8A ±13.8A ±23.3A ±23.3A ±35.4A
Saturation current [Is] ±15A ±25A ±50A ±75A ±150A
Linearity limits 0~±13.5A 0~±22.5A 0~±45A 0~±67.5A 0~±135A
Size of primary winding Φ0.8 Φ1.0 Φ1.3 Φ1.3 Φ1.6
Turns 10 6 3 2 1
Rated output [Vh] ±4V±1.5% (RL=10kΩ)
Residual output [V0] Within ±50mV
Output linearity Within ±1%
Response time Within 10μs (at di/dt=If/μs)
Response performance Within 10%
Hysteresis voltage range Within 60mV
Output Temp. Coef. Within ±0.1%/℃
Residual output Temp. Coef. Within ±2mV/℃
Control power supply ±15V±5%
Consumption current Within 20mA
Operating Temp. -10℃~+80℃
Storage Temp. -15℃~+85℃
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated residual voltage is the one after the core hysteresis is removed.

Consultations and Inquiries about Our Products

Current sensor user's guide

When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.

Click here for FAQs about current sensors

Contact us by e-mail or phone

+81-865-66-4877

PageTop