HC-ASA Medium current range / Bolt on type
Features
- Rated current: 200A–900A
- Small size handles large current (MAX 900A)
- Ensures broad operating temperature range
(-40°C ~ +125°C) - 5V single power supply ratio metric specifica-
tions - Attached to chassis, cable output specifications
Applications
xEV inverters (HEV, EV, PHEV, etc)
Electrical characteristics Ta=25℃
Type | HC-ASA200V2PP5-16 | HC-ASA400V2PP5-16 | HC-ASA600V2PP5-16 | HC-ASA800V2PP5-16 | HC-ASA900V2PP5-16 |
---|---|---|---|---|---|
Rated current [If] | ±200A | ±400A | ±600A | ±800A | ±900A |
Saturation current [Is] | ±220A | ±440A | ±660A | ±880A | ±990A |
Linearity limits | 0~±200A | 0~±400A | 0~±600A | 0~±800A | 0~±900A |
Rated output [Vh] I=+If (RL=10kΩ) | Within V0+2V×(Vcc/5)±1.5% | Within V0+2V×(Vcc/5)±1.7% | |||
Rated output [Vh] I=-If (RL=10kΩ) | Within V0-2V×(Vcc/5)±1.5% | Within V0-2V×(Vcc/5)±1.7% | |||
Residual output [V0] | Within Vcc/2±30mV | ||||
Output linearity | Within ±1% | Within ±1.2% | |||
Response time | Within 10μs (at di/dt=100A/μs) | ||||
Response performance | Within 10% | ||||
Hysteresis voltage range | Within 30mV | Within 22mV | Within 16mV | Within 13mV | |
Output Temp. Coef. | Within ±0.04%/℃ | ||||
Residual output Temp. Coef. | Within ±1mV/℃ | Within ±0.6mV/℃ | Within ±0.5mV/℃ | Within ±0.4mV/℃ | |
Control power supply [Vcc] | +5V±4% | ||||
Power variation characteristics change [+5V±4%] I=±If | 3.5~4.5% | ||||
Power variation characteristics change [+5V±4%] I=0 | 3.2~4.8% | 3.5~4.5% | |||
Consumption current | Within 30mA | ||||
Operating Temp. | -40℃~+125℃ | ||||
Storage Temp. | -40℃~+125℃ | ||||
Dielectric withstand voltage | 2500V AC 50/60Hz 1minute | ||||
Insulation resistance | Not less than 500MΩ 500V DC |
- Note1)
- The indicated residual voltage is the one after the core hysteresis is removed.
- Note2)
- Output specifications include 100-Ω output resistance and 1-mA maximum output current.
- Note3)
- Since residual output is ratiometric output, it varies according to the control power supply value.
- Note4)
- Code at the end of the model name represents harness specifications.
Consultations and Inquiries about Our Products
Current sensor user's guide
When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.
Click here for FAQs about current sensors