Hall-Effect Current Sensor

HC-AK  Medium current range / Bolt on type RoHS compliant

HC-AK

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 200A–500A
  • Small and thin design
  • Bolt-on fixing, Wire harness connection
  • 5V single power supply ratio metric specifica-
    tions
  • Attached to chassis, cable output specifications

Applications

xEV inverters (HEV, EV, PHEV, etc)

Electrical characteristics Ta=25℃

Type HC-AK200V2PP5-1 HC-AK300V2PP5-1 HC-AK400V2PP5-1 HC-AK500V2PP5-1
Rated current [If] ±200A ±300A ±400A ±500A
Saturation current [Is] ±220A ±330A ±440A ±550A
Linearity limits 0~±200A 0~±300A 0~±400A 0~±500A
Rated output [Vh] I=+If Within V0+2V×(Vcc/5)±1.5% (RL=10kΩ)
Rated output [Vh] I=-If Within V0-2V×(Vcc/5)±1.5% (RL=10kΩ)
Residual output [V0] Within Vcc/2±30mV
Output linearity Within ±1%
Response time Within 10μs (at di/dt=100A/μs)
Response performance Within 10%
Hysteresis voltage range Within 30mV Within 22mV Within 16mV Within 13mV
Output Temp. Coef. Within ±0.04%/℃
Residual output Temp. Coef. Within ±2mV/℃ Within ±1.7mV/℃ Within ±1.3mV/℃ Within ±0.9mV/℃
Control power supply [Vcc] +5V±4%
Power variation characteristics change [+5V±4%] I=±If 3.5~4.5%
Power variation characteristics change [+5V±4%] I=0 3~5% 3.1~4.9% 3.2~4.8% 3.3~4.7%
Consumption current Within 30mA
Operating Temp. -40℃~+105℃
Storage Temp. -40℃~+105℃
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated residual voltage is the one after the core hysteresis is removed.
Note2)
Output specifications include 100-Ω output resistance and 1-mA maximum output current.
Note3)
Since residual output is ratiometric output, it varies according to the control power supply value.
Note4)
Code at the end of the model name represents harness specifications.

Consultations and Inquiries about Our Products

Current sensor user's guide

When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.

Click here for FAQs about current sensors

Contact us by e-mail or phone

+81-865-66-4877

PageTop