Fluxgate Current Sensor

HM-A  Medium current range / Bolt on type RoHS compliant

HM-A

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 300A–600A
  • High accuracy current sensor using fluxgate
    technology
  • Very low output noise

Applications

High precision power supply, Medical equipment, High precision inverter, Test equipment

Electrical characteristics Ta=25℃

Output type Current output type
Type HM-A300A02B15B HM-A600A04B15B
Rated current [If] ±300A ±600A
Continuously flowing DC current ±600A ±600A
Min.overload trip current [Is] (Note3) ≧±750A (RL≦5Ω)
≧±850A (RL≦2.5Ω)
Linearity limits (Note4) 0~±650A(RL≦5Ω)
0~±750A(RL≦2.5Ω)
Rated output [Ih] +If I0+200mA±300ppm I0+400mA±300ppm
Rated output [Ih] -If I0-200mA±300ppm I0-400mA±300ppm
Residual output [I0] Within ±10μA
Output linearity Within ±10ppm
Second coil resistance Approx. 16Ω
Response time Within 1μs (at di/dt=100A/μs)
Response performance Within 35%
Hysteresis voltage range Within 15μA
Output Temp. Coef. Within ±5ppm/℃
Residual output Temp. Coef. Within ±0.2μA/℃
Control power supply ±15V±5%
Consumption current 250mA+(Input current/1500)
Operating Temp. +10℃~+50℃
Storage Temp. 0℃~+60℃
Operation status (Photocupuler output) (Note5) Open collector (Imax=6mA Vmax=+15V), Active low (Normal operation)
Dielectric withstand voltage 2500V AC 50/60Hz 1minute
Insulation resistance Not less than 500MΩ 500V DC
Note1)
The indicated residual output is the one after the core hysteresis is removed.
Note2)
Energization time of continuous live DC current x110% shall be within 1 minute.
Note3)
If the current is higher than this, the inside circuit will shut down and the output will be almost zero.
Note4)
Denotes the range of the input current value for which the output is within 0.1% of the estimate output voltage.
Note5)
It is a signal that indicates the inside circuit operation; it indicates Lo level under normal operation, and Hi level when the inner circuit is shut down because of an over current.

Consultations and Inquiries about Our Products

Current sensor user's guide

When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.

Click here for FAQs about current sensors

Contact us by e-mail or phone

+81-865-66-4877