Clamp Type Current Sensor

HA-BV  Clamp type AC-CT RoHS compliant

HA-BV

Dimensional outline drawing

Characteristics charts

Features

  • Rated current: 50A–100A
  • Simple mounting for exiting panel which is clamp type
  • Internal rectification circuit DC-V output type

Applications

Energy measurement unit

Electrical characteristics Ta=25℃

Type HA-B050-V5 HA-B100-V5
Rated primary current [If] 50Arms 100Arms
Measuring bound 10~50Arms 10~100Arms
Frequency 45~65Hz
Rated output voltage DC+5V (Peak)
DC+3.21V (Average)
Ratio error ±3%
Operating Temp. -10℃~+55℃
Storage Temp. -20℃~+60℃
Dielectric withstand voltage 2500V AC 1minute
Insulation resistance Not less than 100MΩ 500V DC
Insulation distance Not less than 8mm
Others Output cable: VCTF wire 0.3mm2, L=2000mm
Output connector: RISE housing 1-178128-2
(AMP) RISE contact 175195-2