Indicator Instruments

Compact Panel Meters

Features

As devices are downsized, demands for smaller meters have increased. In response to this demand, we offer a lineup of compact, high-performance panel meters that take advantage of our long-standing experience in technology for distribution board electric indicating meters.

Applications

Small generators, welding machines, portable power supplies, UPS units, battery chargers, control centers
Agricultural machinery (control panels for rice hullers, rice mills, etc.)
Machine tools (control panels for molding machines, machining centers, etc.), and more

Specifications

Product type KY-600K Series(Note 1) KY-600 Series
For DC For AC For DC For AC
Ammeter Voltmeter Ammeter Voltmeter Frequency meter Ammeter Voltmeter Ammeter Voltmeter Frequency meter
Model KY-602KA KY-602KV KY-601KA KY-601KV KY-603KF KY-602A KY-602V KY-601A KY-601V KY-603F
Cover size 64×60mm
Operating principle Moving coil type Moving iron type Transducer type Moving coil type Moving iron type Transducer type
Intrinsic error ±2.5% for one specified scale point only and ±6% for other scale points (Note 2) 50Hz 60Hz ±1Hz ±2.5% ±1.0%
VA consumption 200mV or less 1mA 1VA 3VA 110V:2.5VA
220V:5VA
200mV or less 1mA 1VA 3VA 110V:2.5VA
220V:5VA
Instrument rating
(Possible manufacturing range)
1mA~30A 1V~300V 1A~30A 100V~300V 100V/110V
200V/220V
45 ~ 55Hz
55 ~ 65Hz
45 ~ 65Hz
1mA~30A 1V~300V 1A~30A 100V~300V 100V/110V
200V/220V
45 ~ 55Hz
55 ~ 65Hz
45 ~ 65Hz
(Notes) 1
The KY-600K series has no zero-adjustment function.
2
The intrinsic error of the KY-600K series is ±2.5% for one specified scale point only and ±6.0% for other scale points. (If not specified, the scale will have approximately 80% of the rated scale value.)
3
We can manufacture extended scales (3 times) for KY-601K and KY-601 AC ammeters. For special extended scales (2 times, 5 times), please consult with us.
4
We can also manufacture the cover with a red pointer for settings.
5
The cover is black. (The lower part of the cover is black from the center.)

Product type KY-500K Series(Note 1) KY-500 Series
For DC For AC For DC For AC
Ammeter Voltmeter Ammeter Voltmeter Frequency meter Ammeter Voltmeter Ammeter Voltmeter
Model KY-502K KY-502K KY-501K KY-501K KY-503K KY-502 KY-502 KY-501 KY-501
Cover size 51×49mm
Operating principle Moving coil type Moving iron type Rectifier type Transducer type Moving coil type Moving iron type Rectifier type
Intrinsic error ±2.5% for one specified scale point only and ±6% for other scale points (Note 2) 50Hz 60Hz ±1Hz ±2.5%
VA consumption 200mV or less 1mA 1VA 2mA 110V:2.5VA
220V:5VA
200mV or less 1mA 1VA 2mA
Instrument rating
(Possible manufacturing range)
1mA~20A 1V~300V 1A~20A 100V~300V 100V/110V
200V/220V
45 ~ 55Hz
55 ~ 65Hz
45 ~ 65Hz
1mA~20A 1V~300V 1A~20A 100V~300V
(Notes) 1
The KY-500K series has no zero-adjustment function.
2
The intrinsic error of the KY-500K series is ±2.5% for one specified scale point only and ±6.0% for other scale points. (If not specified, the scale will have approximately 80% of the rated scale value.)
3
We can manufacture extended scales (3 times) for KY-501K and KY-501 AC ammeters. For special extended scales (2 times, 5 times), please consult with us.
4
We can also manufacture the cover with a red pointer for settings.
5
The cover will be diamond cut (all transparent acrylic without paint).

Product type KY-450K Series KY-450 Series
For DC For AC For DC For AC
Ammeter Voltmeter Ammeter Voltmeter Ammeter Voltmeter Ammeter Voltmeter
Model KY-452K KY-452K KY-451K KY-451K KY-452 KY-452 KY-451 KY-451
Cover size 45×42mm
Operating principle Moving coil type Moving iron type Rectifier type Moving coil type Moving iron type Rectifier type
Intrinsic error ±2.5% for one specified scale point only and ±6% for other scale points (Note 1) ±3.0%
VA consumption 200mV or less 1mA 1VA 2mA 200mV or less 1mA 1VA 2mA
Instrument rating
(Possible manufacturing range)
Stud terminal type
1mA~5A 1V~300V 1A~20A 100V~300V 1mA~5A 1V~300V 1A~20A 100V~300V
Instrument rating
(Possible manufacturing range)
Tab terminal type
1mA~5A 1V~300V 1A~5A 100V~300V 1mA~5A 1V~300V 1A~5A 100V~300V
(Notes) 1
The intrinsic error of the KY-450K series is ±2.5% for one specified scale point only and ±6.0% for other scale points. (If not specified, the scale will have approximately 80% of the rated scale value.)
2
We can manufacture extended scales (3 times) for KY-451K and KY-451 AC ammeters. For special extended scales (2 times, 5 times), please consult with us.
3
We can also manufacture the cover with a red pointer for settings.
4
The cover is made of transparent acrylic without paint.
5
The allowable thickness of the mounting panel is t1.6 to t2.3.
6
Panel mounting method: We can manufacture panels with mounting studs (M3 screws) upon request. (Attachment is not provided for panels with mounting studs.) The panel mounting hole diameter is 3.2.

Instrument External Dimensions

KY-450K/KY-450
Series Instrument
External Dimensions

KY-500K/KY-500 Series Instrument External Dimensions

KY-600K/KY-600 Series Instrument External Dimensions

Product information reference

Contact us by e-mail or phone

+81-84-983-2070

PageTop