Compact Panel Meters

Features
Applications
Small generators, welding machines, portable power supplies, UPS units, battery chargers, control centers
Agricultural machinery (control panels for rice hullers, rice mills, etc.)
Machine tools (control panels for molding machines, machining centers, etc.), and more
Specifications
Product type | KY-600K Series(Note 1) | KY-600 Series | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
For DC | For AC | For DC | For AC | |||||||
Ammeter | Voltmeter | Ammeter | Voltmeter | Frequency meter | Ammeter | Voltmeter | Ammeter | Voltmeter | Frequency meter | |
Model | KY-602KA | KY-602KV | KY-601KA | KY-601KV | KY-603KF | KY-602A | KY-602V | KY-601A | KY-601V | KY-603F |
Cover size | 64×60mm | |||||||||
Operating principle | Moving coil type | Moving iron type | Transducer type | Moving coil type | Moving iron type | Transducer type | ||||
Intrinsic error | ±2.5% for one specified scale point only and ±6% for other scale points (Note 2) | 50Hz 60Hz ±1Hz | ±2.5% | ±1.0% | ||||||
VA consumption | 200mV or less | 1mA | 1VA | 3VA | 110V:2.5VA 220V:5VA |
200mV or less | 1mA | 1VA | 3VA | 110V:2.5VA 220V:5VA |
Instrument rating (Possible manufacturing range) |
1mA~30A | 1V~300V | 1A~30A | 100V~300V | 100V/110V 200V/220V 45 ~ 55Hz 55 ~ 65Hz 45 ~ 65Hz |
1mA~30A | 1V~300V | 1A~30A | 100V~300V | 100V/110V 200V/220V 45 ~ 55Hz 55 ~ 65Hz 45 ~ 65Hz |
- (Notes) 1
- The KY-600K series has no zero-adjustment function.
- 2
- The intrinsic error of the KY-600K series is ±2.5% for one specified scale point only and ±6.0% for other scale points. (If not specified, the scale will have approximately 80% of the rated scale value.)
- 3
- We can manufacture extended scales (3 times) for KY-601K and KY-601 AC ammeters. For special extended scales (2 times, 5 times), please consult with us.
- 4
- We can also manufacture the cover with a red pointer for settings.
- 5
- The cover is black. (The lower part of the cover is black from the center.)
Product type | KY-500K Series(Note 1) | KY-500 Series | |||||||
---|---|---|---|---|---|---|---|---|---|
For DC | For AC | For DC | For AC | ||||||
Ammeter | Voltmeter | Ammeter | Voltmeter | Frequency meter | Ammeter | Voltmeter | Ammeter | Voltmeter | |
Model | KY-502K | KY-502K | KY-501K | KY-501K | KY-503K | KY-502 | KY-502 | KY-501 | KY-501 |
Cover size | 51×49mm | ||||||||
Operating principle | Moving coil type | Moving iron type | Rectifier type | Transducer type | Moving coil type | Moving iron type | Rectifier type | ||
Intrinsic error | ±2.5% for one specified scale point only and ±6% for other scale points (Note 2) | 50Hz 60Hz ±1Hz | ±2.5% | ||||||
VA consumption | 200mV or less | 1mA | 1VA | 2mA | 110V:2.5VA 220V:5VA |
200mV or less | 1mA | 1VA | 2mA |
Instrument rating (Possible manufacturing range) |
1mA~20A | 1V~300V | 1A~20A | 100V~300V | 100V/110V 200V/220V 45 ~ 55Hz 55 ~ 65Hz 45 ~ 65Hz |
1mA~20A | 1V~300V | 1A~20A | 100V~300V |
- (Notes) 1
- The KY-500K series has no zero-adjustment function.
- 2
- The intrinsic error of the KY-500K series is ±2.5% for one specified scale point only and ±6.0% for other scale points. (If not specified, the scale will have approximately 80% of the rated scale value.)
- 3
- We can manufacture extended scales (3 times) for KY-501K and KY-501 AC ammeters. For special extended scales (2 times, 5 times), please consult with us.
- 4
- We can also manufacture the cover with a red pointer for settings.
- 5
- The cover will be diamond cut (all transparent acrylic without paint).
Product type | KY-450K Series | KY-450 Series | ||||||
---|---|---|---|---|---|---|---|---|
For DC | For AC | For DC | For AC | |||||
Ammeter | Voltmeter | Ammeter | Voltmeter | Ammeter | Voltmeter | Ammeter | Voltmeter | |
Model | KY-452K | KY-452K | KY-451K | KY-451K | KY-452 | KY-452 | KY-451 | KY-451 |
Cover size | 45×42mm | |||||||
Operating principle | Moving coil type | Moving iron type | Rectifier type | Moving coil type | Moving iron type | Rectifier type | ||
Intrinsic error | ±2.5% for one specified scale point only and ±6% for other scale points (Note 1) | ±3.0% | ||||||
VA consumption | 200mV or less | 1mA | 1VA | 2mA | 200mV or less | 1mA | 1VA | 2mA |
Instrument rating (Possible manufacturing range) Stud terminal type |
1mA~5A | 1V~300V | 1A~20A | 100V~300V | 1mA~5A | 1V~300V | 1A~20A | 100V~300V |
Instrument rating (Possible manufacturing range) Tab terminal type |
1mA~5A | 1V~300V | 1A~5A | 100V~300V | 1mA~5A | 1V~300V | 1A~5A | 100V~300V |
- (Notes) 1
- The intrinsic error of the KY-450K series is ±2.5% for one specified scale point only and ±6.0% for other scale points. (If not specified, the scale will have approximately 80% of the rated scale value.)
- 2
- We can manufacture extended scales (3 times) for KY-451K and KY-451 AC ammeters. For special extended scales (2 times, 5 times), please consult with us.
- 3
- We can also manufacture the cover with a red pointer for settings.
- 4
- The cover is made of transparent acrylic without paint.
- 5
- The allowable thickness of the mounting panel is t1.6 to t2.3.
- 6
- Panel mounting method: We can manufacture panels with mounting studs (M3 screws) upon request. (Attachment is not provided for panels with mounting studs.) The panel mounting hole diameter is 3.2.
Instrument External Dimensions
KY-450K/KY-450
Series Instrument
External Dimensions
KY-500K/KY-500 Series Instrument External Dimensions
KY-600K/KY-600 Series Instrument External Dimensions