HB-10RS Clamp type DC-CT
Features
- Rated primary current: 15A
- Connector Specifications
- Simple mounting for exiting panel which is clamp type
Applications
Energy measurement unit , power supply equipment
Electrical characteristics Ta=25℃
Type | HB-10R015V4B12C | HB-10R015V2PP5C |
---|---|---|
Rated current | ±15A | |
Saturation current | ±33.75A | ±16.5A |
Linearity limits | 0~±30A | 0~±15A |
Rated output | Within ±4V±4.5% (RL=10kΩ) | Within V0±2V±90mV(RL=10kΩ) |
Residual output | Within ±150mV | (Vcc/2)Within±75mV |
Output linearity | Within ±1% | |
Response time | Within 10μs | Within 30μs |
Response performance | Within 10% | |
Hysteresis voltage range | Within 100mV | Within 50mV |
Output Temp. Coef. | Within ±0.15%/℃ | |
Residual output Temp. Coef. | Within ±14mV/℃ | Within ±7mV/℃ |
Control power supply | ±12V±5% | +5V±5% |
Consumption current | Within 20mA | Within 15mA |
Operating Temp. | -10℃~+80℃ | |
Storage Temp. | -20℃~+85℃ | |
Dielectric withstand voltage | 2500V AC 1minute | |
Insnlation resistance | Not less than 500MΩ 500V DC |
- Note1)
- The indicated residual output is the one after the core hysteresis is removed.
- Note2)
- Output specifications include 100-Ω output resistance and 2-mA maximum output current.
Consultations and Inquiries about Our Products
Current sensor user's guide
When using our current sensors, please read the following “Handling Precautions,” “Main Characteristics,” and “Product Labeling” and use them within the specified limits.
Click here for FAQs about current sensors