Topic Path
- HOME
- Products
- Current Sensor
- HS-PTA
HS-PTA Small current range / Bolt on type
Feature
- Rated current: 50A–100A
- Three circuits can be measured at the same time
- Realized high precision and compact size
- Superior in response, linearity and temperature characteristics
- Both the voltage output and the current output were prepared
Inverters, Servo drivers, Power supply equipment, NC machine tools
DataSheet
Standard catalogTa=25℃
Output type | Current output type | |
---|---|---|
Type | HS-PTA050A00125B15 | HS-PTA100A0025B15 |
Rated current [If] | ±50A | ±100A |
Continuously flowing DC current | ±50A | ±100A |
Saturation current [Is] | ±150A | ±200A |
Linearity limits | 0~±150A (RL=10~100Ω) | 0~±200A (RL=10~50Ω) |
Rated output [Ih] | I0±12.5mA±1% | I0±25mA±1% |
Residual output [I0] | Within ±0.2mA | |
Output linearity | Within ±0.3% | |
Second coil resistance | Approx. 120Ω | |
Response time | Within 1μs (The smaller one on either at di/dt = 100A/μs or If/μs.) | |
Response performance | Within 10% | |
Hysteresis voltage range | Within 0.2mA | |
Output Temp. Coef. | Within ±0.02%/℃ | |
Residual output Temp. Coef. | Within ±0.01mA/℃ | |
Control power supply | ±15V±5% | |
Consumption current | 60mA+(Input current/4000) | |
Operating Temp. | -15℃~+80℃ | |
Storage Temp. | -25℃~+85℃ | |
Dielectric withstand voltage | 2500V AC 50/60Hz 1minute | |
Insulation resistance | Not less than 500MΩ 500V DC |
- Note1)
- The indicated residual voltage is the one after the core hysteresis is removed.
- Note2)
- Energization time of saturation current shall be within 1 second.
- Note3)
- Energization time of continuous live DC current x150% shall be within 1 minute.