Topic Path
- HOME
- Products
- Current Sensor
- HP-AR
HP-AR Medium current range / Bolt on type
Feature
- Rated current: 200A–1150A
- Tri-phase current sensor in the same housing (Good fit 47mm/48mm pitch IGBT Modules)
- Operating temperature range: -40℃ to +125℃
- Use high performance programmable Hall IC
- 5V single power supply, ratiometric output (sensitivity and offset)
xEV inverters (HEV, EV, PHEV, etc)
DataSheet
Standard catalogTa=25℃
Type | HP-AR200V2PP5 | HP-AR400V2PP5 | HP-AR600V2PP5 | HP-AR800V2PP5 | HP-ARE115V2PP5 |
---|---|---|---|---|---|
Rated current [If] | ±200A | ±400A | ±600A | ±800A | ±1150A |
Output voltage [Vout] | Vout=(Vcc/5)・(V0+G・Ip) (Note3) | ||||
Sensitivity [G] (Note4) | 10mV/A | 5mV/A | 3.33mV/A | 2.5mV/A | 1.74mV/A |
Load resistance [RL] | ≧2.5kΩ | ||||
Sensitivity error I=±If | ±1% | ±1.5% | |||
Offset voltage [V0] I=0 | Vref ±18mV (Vref=Vcc/2) | ||||
Output linearity | Within ±1% | ||||
Response time | Within 5μs (at di/dt=100A/μs) @LPF(fc=133kHz) connected | ||||
Response performance | Within 10% (at di/dt=100A/μs) @LPF(fc=133kHz) connected | Within 15% (at di/dt=100A/μs) @LPF(fc=133kHz) connected | |||
Hysteresis voltage range | ±22mV | ±15mV | ±12mV | ±10mV | ±9mV |
Sensitivity Temp. Coef. | ±3% | ||||
Offset voltage Temp. Coef. | ±30mV | ||||
Control power supply [Vcc] | +5V±5% | ||||
Ratiometricity error [+5V±5%] Sensitivity |
±0.5% | ||||
Ratiometricity error [+5V±5%] Offset voltage |
±0.4% | ||||
Consumption current | Within 40mA | ||||
Operating Temp. | -40℃~+125℃ | ||||
Storage Temp. | -40℃~+125℃ | ||||
Dielectric withstand voltage | 2500V AC 50/60Hz 1minute | ||||
Insulation resistance | Not less than 500MΩ 500V DC |
- Note1)
- The indicated offset voltage is the one after the core hysteresis is removed.
- Note2)
- Output specifications: maximum output current ≦2mA, Load capacitance ≦100pF
- Note3)
- Vcc: Control power supply, V0: Offset voltage, G: Sensitivity, Ip: Primary current
- Note4)
- Sensitivity: G=2000mV/If