Topic Path
- HOME
- Products
- Current Sensor
- HC-TNG
HC-TNG Medium current range / Bolt on type
Feature
- Rated current: 50A–800A
- Superior noise-resistance
- Low-profile realized to our conventional products (HC-TN)
- Well isolated for European Standards
- Bus bar mounting type
Inverters, Servo drivers, Power supply equipment, Uninterruptible power supply (UPS), NC machine tools, Welders
DataSheet
Standard catalogTa=25℃
Type | HC-TNG050V4B15 | HC-TNG100V4B15 | HC-TNG300V4B15 | HC-TNG600V4B15 | HC-TNG800V4B15 |
---|---|---|---|---|---|
Rated current [If] | ±50A | ±100A | ±300A | ±600A | ±800A |
Saturation current [Is] | ±150A | ±300A | ±900A | ±1000A | |
Linearity limits | 0~±150A | 0~±300A | 0~±700A | 0~±900A | |
Rated output [Vh] RL=10kΩ | V0±4V±1% | ||||
Residual output [V0] | Within ±50mV | Within ±30mV | |||
Output linearity | Within ±1% | ||||
Response time | Within 5μs (The smaller one on either at di/dt = 100A/μs or If/μs.) | ||||
Response performance | Within 10% | ||||
Hysteresis voltage range | Within 30mV | ||||
Output Temp. Coef. | Within ±0.1%/℃ | ||||
Residual output Temp. Coef. | Within ±3mV/℃ | Within ±1.5mV/℃ | Within ±1mV/℃ | ||
Control power supply | ±15V±5% | ||||
Consumption current | Within 20mA | ||||
Operating Temp. | -25℃~+85℃ | ||||
Storage Temp. | -25℃~+85℃ | ||||
Dielectric withstand voltage | 4000V AC 50/60Hz 1minute | ||||
Insulation resistance | Not less than 500MΩ 500V DC |
- Note1)
- The indicated residual voltage is the one after the core hysteresis is removed.